Omron V680-CA5D01-V2 User Manual page 132

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

COPY (CP)
The COPY command reads data from the memory of a Tag using one Antenna and writes it to the
memory of the Tag in the other Antenna's communications area. This command cannot be used with
the V680-CA5D01-V2.
1:1 Protocol
Command
Antenna
designation
Communi-
Data
cations
desig-
Command
designation
nation
code
×
×
C
P
H
1/2
2
2
1
1
Communications
designation
Data designation
Antenna designation
UID
Read area start address
No. of bytes to copy
Destination start address
The communications designation for the Antenna that reads data is always single trigger (ST). The communications
designation specified in the command is used for the Antenna that writes data.
For a communications designation that specifies repeating, data writing will be repeated for other Tags after data is writ-
ten to the first Tag.
Response
Antenna
Resend flag
desig-
Command
End code
code
nation
×
×
0
0
C
P
0
2
2
1
1
Note: When using the multi-access trigger communications designation (MT), the ID controller returns
an end code of 03 after communicating with all Tags.
UID
UID
Read area start address
...
×
×
×
×
×
×
×
0 or 16
4
Specifies the method of communications with the Tag.
Refer to Communications Designation Function for details on the communications designation.
p. 103
Always "H".
Specifies the Antenna with which to communicate.
"1": Reads from Antenna 1 and writes to Antenna 2.
"2": Reads from Antenna 2 and writes to Antenna 1.
A unique identifier used to identify Tags.
Only in the case of the selective communications designation (SL), the UID of the Tag that is
being written to is added to the data.
Specifies the start address of the area in the Tag from which data is to be read from in 4-digit
hexadecimal.
Setting range: 0000
to FFFF
H
H
Specifies the number of bytes of data to copy in 4-digit hexadecimal.
Setting range: 0001
to 0800
H
H
Specifies the start address of the area in the Tag to which data is to be written in 4-digit hexadec-
imal.
Setting range: 0000
to FFFF
H
H
UID
Terminator
×
×
×
*
...
CR
0 or 16
2
A unique identifier used to identify Tags.
In the case of multi-access communications designations (MT/MR), the UID of the Tag that is
being written to is added to the data.
No. of bytes to copy Destination start address Terminator
×
×
×
×
×
×
×
4
4
SECTION 5
Communications
×
×
*
CR
2
RFID System
User's Manual
129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents