Connecting to Ethernet
The ID Controller can be connected to the host device through an OMRON ITNC-SGB01 Serial Gate
Box to enable Ethernet TCP/IP communications. An ID Controller connected through a Serial Gate Box
can be communicated with in exactly the same way as when the ID Controller is connected through the
serial interface.
Serial Gate Box
GR
SG
RD
SD
RS
CS
(Shield)
Refer to the ITNC-SGB01 Serial Gate Box manual for details on the Serial Gate Box.
1:1 Connection
Personal computer
Serial Gate Box
ITNC-SGB01
RS-232C
ID Controller
1:N Connections
Personal computer
Serial Gate Box
ITNC-SGB01
RS-232C
RS-422/RS-485
ID Controller
ID Controller
GR
SG
SD
RD
RS
Model
CS
ITNC-SGB01
10Base-T/100Base-TX
10Base-T/100Base-TX
RS-422/RS-485
ID Controller
ID Controller
Installation, Connections, and Wiring
Rated power supply volt-
Power consump-
age
DC24V +10%
− 15%
RS-422/RS-485
ID Controller
SECTION 2
tion
3 W max.