Omron V680-CA5D01-V2 User Manual page 66

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

SW4, pin 8 (V680-H01 Antenna connection setting)
SW4, pin 8
OFF
Connection to antennas other than the V680-H01
ON
Allows connection of the V680-H01 Antenna.
The V680-H01 Antenna can be connected only to the V680-CA5D01-V2 ID Controller. It cannot be used with the V680-
CA5D02-V2 ID Controller.
SW4, Pin 9 (Run Mode)
SW4, pin 9
OFF
Command Execution Mode
ON
Self-execution Mode
Self-execution Mode will not work if pin 10 on DIP switch SW3 (V600 commands) is ON.
SW4-10 (High-speed Data Transmission setting)
SW4, pin 8
OFF
Normal mode
ON
High-speed mode
The high-speed mode cannot be used with the V680-H01 Antenna.
For information on communication times, refer to Tag Communications Time and Turn Around Time (Reference).
When using multi-access, selective, or FIFO communications options, normal-mode communications speed will be
used regardless of this setting.
p. 257
Mode Switch Setting
SW5
OFF
Run Mode
ON
Maintenance Mode
Maintenance Mode cannot be used when the V680-H01 Antenna is connected.
Terminating Resistance
If two or more ID Controller are connected to one host device, be sure to turn ON the terminating resis-
tance of only the Controllers or host devices at each end of the serial connection and turn OFF the ter-
minating resistance of any other device. Incorrect settings will result in unstable operation.
This switch is used to set internal terminating resistance.
SW6
OFF
Terminating resistance OFF
ON
Terminating resistance ON
Preparations for Communications
Description
Description
Description
Description
Description
SECTION 3
RFID System
63
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents