SECTION 3
Preparations for Communications
Controller Number Switch Settings (SW1, SW2)
Controller Numbers
If more than one Controller is connected to a single host device, the host device must be able to distin-
guish them. For this reason, a different Controller number must be set for each Controller.
Controller numbers are included in 1:N protocol commands and responses. Communications are not
possible if the Controller numbers are not set correctly.
SW1 and SW2 are enabled only when the DIP switch is enabled (i.e., when pin 1 on SW3 is OFF). If the internal set-
tings are enabled (i.e., if pin 1 on SW3 is ON), the values specified by the PARAMETER SET (SP) command will be
enabled.
Setting Controller Numbers
SW1
Upper digit
0
0
0
0
0
0
0
0
0
0
1
1
:
2
3
3
3
3
:
9
The Controller number switch is factory-set to 00.
Do not set the Controller number switch to between 32 and 99.
When rotary switch SW1 is set to 8, the ID Controller will be in Host Communications Trigger Send Mode. If the mode
switch is turned OFF in this mode, a response frame will be sent to the host device.
RFID System
60
User's Manual
p. 230
SW2
Controller No.
Lower digit
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
10
1
11
:
:
9
29
0
30
1
31
2
Setting prohibited
3
Setting prohibited
:
:
9
Setting prohibited
p. 74
Setting Examples
SW1
0
5
SW2
0
5
Controller No. 17
Controller No. 0
SW1
0
5
SW2
0
5