(2) A class 2 circuit with a maximum voltage of 30 Vrms (42.4 V peak) that uses a class 2 power supply unit
conforming to UL1310 or a class 2 transformer that conforms to UL1585 as its power source.
2. EMC Standards
The V680-CA5D01-V2 and V680-CA5D02-V2 meet the requirements of the following EC Directives.
EMC Standard: EN 61000-6-2
Be sure to observe the following precautions to ensure safe use of the Product.
1. Do not use the Product in environments with flammable, explosive, or corrosive gasses.
2. Do not attempt to disassemble, repair, or modify the Product.
3. Tighten the base mounting screws and terminal block screws securely.
4. Be sure to use crimp terminals of the specified size for wiring.
5. If any cable has a locking mechanism, make sure that it has been locked before using the cable.
6. Make sure the power supplied by the DC power supply unit is within the rated power supply voltage (24
VDC +10%/ − 15%) before using the Product.
7. Do not connect the power supply in reverse.
8. Do not allow water or wires to enter the Product through gaps in the case. Otherwise, fire or electric shock
may occur.
9. Turn OFF the power to the Controller before attaching or removing an Amplifier or Antenna.
10.If an error is detected in the Product, immediately stop operation and turn OFF the power supply.
Consult with an OMRON representative.
11.Dispose of the Product as industrial waste.
12.Observe all warnings and precautions given in the body of this manual.