SECTION 5
Communications
3. Set the Output Conditions
Command
Command
Process
code
code
S
E
0
2
2
Note: There are the following three patterns for comparison conditions A and B depending on the con-
ditions.
• When Data Criteria Are Used for Conditions A and B
Comparison
parameters A and B
×
×
×
4
• When "ER" Is Specified as the Communications Criteria for Conditions A and B
Comparison parameters A and B
×
×
×
• When "OK" or "AL" Is Specified as the Communications Judgements Conditions A and B
There are no parameters in this case.
Process code
Operation condition parameter
Comparison antenna
Conditions
A and B
Data offsets A and B
Number of data bytes A and B
Compari-
son param-
eters A and
B
Operator
Output parameter
Response
Command
code
End code
×
S
E
2
2
RFID System
154
User's Manual
Compari-
Operation
condition
son
parameter
antenna
Condition A
×
×
×
×
×
×
0
2
2
2
Number of data
Comparison parameters
bytes A and B
A and B
×
×
×
×
×
...
2
n
×
×
×
×
×
8
Always "00".
"S1": OUT1 output condition setting
"S2": OUT2 output condition setting
"S3": OUT3 output condition setting
"S4": OUT4 output condition setting
Note: "S3" or "S4" will result in an error (15) in Two Output Mode. Also, if output conditions
are not set for OUT1 through OUT3, the execution command output destination cannot be
set.
"01": Compare to channel 1
"02": Compare to channel 2
"XX": No output
Data criteria
"==": Criteria data match, "!=": Criteria data does not match,
">=": Equal to or higher than criteria, "<=": Equal to or less than criteria,
Data criteria can be used only for READ commands.
Communications cri-
"OK": Communication OK, "ER": Communications error, "AL": Always
teria
Specifies the offset to the portion of the read data to use as the criteria.
Setting range: 0000
Specifies the number of bytes to use as the criteria.
Setting range: 01
When conditions A
Specifies the comparison data to use as the data criteria.
and B are data crite-
(The same length as the designated number of data bytes for either ASCII and hexadeci-
ria
mal data.)
When conditions A
Specifies the error code.
and B are "ER" com-
"00000000" specifies all error codes.
munications criteria
Example: "707A0000"specifies a Tag communications error and address error.
Operator between condition A and condition B
"&&": AND, "++": OR
Specifies the output ON time in milliseconds.
Setting range: "0001" to "9999" (ms), ("0000": Hold until next judgment)
Fixed
Resend
value
flag
Terminator
×
*
0
0
CR
1
1
2
Comparison
parameter A
Operator
Condition B
×
...
×
×
×
×
×
×
n
2
2
to FFFF
H
H
to 10
H
H
Comparison
parameter B
Output parameter
Terminator
...
×
×
×
×
×
*
n
4
CR
2