Omron V680-CA5D01-V2 User Manual page 147

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

SECTION 5
Communications
CONTROLLER CONTROL Commands
UID ADDITION SET (US)
Sets whether or not UID should be added to the read command (RD) response or read tag memory
error correction (QR) response.
1:1 Protocol
Command
Process
Command
desig-
code
nation
×
U
S
2
1
Process designation
Response
Command
End code
code
U
S
0
2
2
1:N Protocol
Command
Controller No.
×
@
0
1
1
Process designation
Response
Controller No.
×
@
0
1
1
RFID System
144
User's Manual
Fixed
Terminator
value
*
0
CR
1
2
Specify whether or not to add a UID.
"0": Do not add a UID
"1" Add a UID
Resend flag
Fixed
value
Terminator
*
0
0
0
CR
1
1
2
Process
desig-
Fixed
Command
nation
FCS
value
code
×
×
×
×
U
S
0
2
2
1
1
2
Specify whether or not to add a UID.
"0": Do not add a UID
"1" Add a UID
Resend flag
Command
Fixed
code
End code
value
×
0
0
U
S
0
0
2
2
2
1
1
Terminator
*
CR
2
FCS
Terminator
*
×
×
C R
2
2

Hide quick links: