List of End Codes
End codes are expressed in 2-digit hexadecimal.
Classification
End code
Normal end
Host communications
error
Tag communications error
System error
Refer to Error Lists for details on error checks.
p. 240
00
Normal end
Command processing terminated.
Polling command query (after communications with Tag were completed normally)
Polling command cancelled.
Normal end (no error) for DATA CHECK command or OVERWRITE COUNT
CONTROL command
01
Polling command received.
02
Polling command query (no results information)
03
Multi-access communications ended
10
Parity error
11
Framing error
12
Overrun error
13
FCS error
14
Format error
15
Execution condition error
18
Frame length error
70
Tag communications error
71
Mismatch error
72
Tag missing error
76
Error end (verification error or overwrite count exceeded) for DATA CHECK
command, OVERWRITE COUNT CONTROL command or Data check error in
READ TAG MEMORY ERROR CORRECTION command
77
Data check warning in READ TAG MEMORY ERROR CORRECTION command
79
Tag error
7A
Address error
7C
Antenna not connected error
7D
Write protected error
92
Antenna internal power supply voltage error
93
Internal memory error
Number of Antennas error
9C
Former Antenna setting error
SECTION 5
Communications
Name
RFID System
171
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents