1:N Protocol
Antenna
Command
designation
Data
Command
desig-
Controller No.
code
nation
×
×
@
W
T
A/H
1/2
3
2
1
1
Data designation
Antenna designation
Write area start address
Write data
Response
Command
Controller No.
End code
code
×
×
@
W
T
0
3
2
2
End code
Write area start
Write data
address
×
×
×
×
×
×
×
4
n
Specifies the code format when sending the Tag write data.
"A": ASCII
"H": Hexadecimal
Specifies the Antenna with which to communicate.
"1": Antenna 1
"2": Antenna 2
Specifies the start address of the area in the Tag to which data is to be written in 4-digit
hexadecimal.
Setting range: 0000
to FFFF
H
H
Specified the data to be written to the Tag.
Up to 256 bytes can be written with one command.
• ASCII: 256 bytes (256 characters)
• Hexadecimal: 256 bytes (512 characters)
Note: When hexadecimal is designated, set two characters for each byte.
FCS
Terminator
×
×
*
0
CR
2
2
Indicates the execution result for the command.
"00" indicates a normal end.
Refer to List of End Codes for information on other end codes.