Omron V680-CA5D01-V2 User Manual page 162

V680 series rfid system id controller
Hide thumbs Also See for V680-CA5D01-V2:
Table of Contents

Advertisement

RESPONSE RESEND (RR)
The RESPONSE RESEND command causes the ID Controller to resend the most recent response.
The RESPONSE RESEND command cannot be used to reset a response for the LARGE READ (ER) command.
1:1 Protocol
Command
Command
Terminator
code
*
R
R
CR
2
2
When There Was an Immediately Preceding Response
The ID Controller resends the most recent response, but sets the Resend Flag to "1". The response
formats are the same as for the individual commands.
When There Was No Immediately Preceding Response
Response
Resend flag
Command
Fixed
End code
Terminator
code
value
×
×
R
R
0
0
2
2
1
1
1:N Protocol
Command
Command
Controller No.
code
×
×
R
R
@
0
2
2
1
1
When There Was an Immediately Preceding Response
The ID Controller resends the most recent response, but sets the Resend Flag to "1".
The response formats are the same as for the individual commands.
When There Was No Immediately Preceding Response
Response
Command
Controller No.
code
×
×
@
0
R
R
1
1
2
2
*
CR
2
Terminator
FCS
×
*
×
CR
2
2
Resend flag
Fixed
End code
FCS
Terminator
value
*
×
×
×
×
0
0
2
1
1
2
2
CR
SECTION 5
Communications
RFID System
159
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca5d02-v2

Table of Contents