Conversion Instructions
Variations
Operands
Operand Specifications
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
C: Control Word
Specifies the signed BCD format. C must be 0000 to 0003.
S: First Source Word
Source words S+1 and S contain the double signed binary data to be con-
verted. Their content must be within the valid range of the BCD format speci-
fied in C.
Setting
C=0000
FF67 6981 to FFFF FFFF or 0000 0000 to 0098 967F
C=0001
FB3B 4C01 to FFFF FFFF or 0000 0000 to 04C4 B3FF
C=0002
FF67 6981 to FFFF FFFF or 0000 0000 to 05F5 E0FF
C=0003
FECE D301 to FFFF FFFF or 0000 0000 to 05F5 E0FF
D: First destination word
Destination words D+1 and D contain the converted double signed BCD data.
See the description section below for an explanation of the BCD formats.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Allowed values for S+1 and S
C
CIO 0000 to
CIO 0000 to CIO 6142
CIO 6143
W000 to W511
W000 to W510
H000 to H511
H000 to H510
A000 to A959
A000 to A958
T0000 to T4095
T0000 to T4094
C0000 to C4095
C0000 to C4094
D00000 to
D00000 to D32766
D32767
E00000 to
E00000 to E32766
E32767
En_00000 to
En_00000 to En_32766
En_32767
(n = 0 to C)
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
#0000 to #0003
---
(binary)
DR0 to DR15
---
Section 3-12
BDSL(473)
@BDSL(473)
Not supported
S
D
A448 to A958
527