Omron SYSMAC CJ - REFERENCE MANUAL 01-2008 Reference Manual page 573

Sysmac cs/cj/one nsj series programmable controllers
Table of Contents

Advertisement

Conversion Instructions
15
C: D00000
C+1: D00001
Zero point offset: 001A hex
C+2: D00002
User-specified resolution: Not used.
S: 0010
0
D: D00200
D+1: D00201
534
Example 1: Converting to Binary Data with an 8-bit Resolution and Zero
Point Offset of 001A Hex
12
11
8
7
0
0
0
Operating mode: Gray binary code conversion
001A
0
000
0
0
0
0
0
0
0
0
0
1
Converted and offset.
0017
0000
Example 2: Converting to Angle Data with a 10-bit Resolution and Zero
Point Offset of 0151 Hex
15
C: D00000
C+1: D00001
Zero point offset: 0151 hex
C+2: D00002
User-specified resolution: Not used.
S: 0010
0
0
D: D00200
D+1: D00201
4 3
0
8
Resolution: 8-bit
Conversion mode: Binary Mode
0
1
0
0
1
Gray binary code
Result of binary conversion and offsetting stored.
12
11
8
7
4 3
0
0
2
Conversion mode: 360 Mode
Operating mode: Gray binary code conversion
0151
0
000
0
0
0
0
0
1
1
0
1
0
Converted and offset.
3488
0000
Section 3-12
0
A
Resolution: 10-bit
1
0
0
1
Gray binary code
Angle data stored.