3-12-13 LINE TO COLUMN: COLM(064)

Purpose
Ladder Symbol
Variations
Applicable Program Areas
Operands
Name
Label
Error Flag
ER
Equals Flag
=
When CIO 000000 is ON in the following example, LINE(063) copies bit 5
from D00100 to D00115 to the 16 bits in D00200.
&5
Converts the 16 bits of the source word to a column of bits in a 16-word range
of destination words (the same bit number in 16 consecutive words).
COLM(064)
S
D
N
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Block program areas
OK
OK
D: First Destination Word
Specifies the first destination word. D and D+15 must be in the same data
area.
Operation
ON if N is not within the specified range of 0000 to 000F.
OFF in all other cases.
ON if D is 0000 after execution.
OFF in all other cases.
S:
to
D: D00200
S: Source word
D: First destination word
N: Bit number
Step program areas
Subroutines
OK
Section 3-12
N: #0005
to
COLM(064)
@COLM(064)
Not supported
Interrupt tasks
OK