BALL GATE NOT OPERATING PROPERLY

The ball gate will normally be up to stop balls.
It will cycle down to allow balls to pass over it during game play.
To test - Press the menu button to enter the main menu.
Press menu button to get to "Diagnostic", then press the menu
select button to scroll to the Gate Diagnostics.
Press the right Versus Head to Head Button to lower the gate.
Press the left Single Player Button to raise the gate.
When a button is pressed to move the motor, the "M" will change to "ON" until motor stops.
The "S" will flash "OFF" as the sensor is blocked.
Verify that the balls roll smoothly to the player.
Press the left Single Player Button to raise the gate.
Verify that the balls are being blocked by the ball gate.
If any adjustments need to be made for the ball gate height, refer to "How to Adjust the Ball Gate"
The ball gate movement is controlled by a sensor attached
to the motor.
The sensor watches a cam with a solid end and a forked end.
- When the gate is up, the motor will stop past the forked end of the
cam.
AACB5190A
Sensor for Motor
- When the gate is down, the motor will stop past the solid end of the cam.
If the ball gate motor is timing out after about 1 revolution, this sensor is not
seeing the cam at all. Check cable connections and replace sensor if needed.
If the motor is not turning at all, refer to wiring diagrams and check wiring,
check for 12 volts DC at the motor while selecting open/close gate in the menu.
Normally 4 Ohms across the motor.
Replace motor if needed. Part # A5MO5154