Lutcontrol - IAI GOX-5105M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Table of Contents

Advertisement

GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE
Analog Control
Setting Range
Item
Gamma
Related Topic:
0.45~1
Gamma
Function
0: Off
LUTMode
1: Gamma
2: LUT

LUTControl

Configure LUT settings.
Related Topic:
LUT (Lookup Table)
LUT Control Item
LUTSelector
LUTIndex
LUTValue
Default
Value
Set the gamma value.
0.45
Setting Range: 0.45, 0.50, 0.55, 0.60, 0.65, 0.75, 0.80, 0.90, 1.00
0:Off
Select the LUT mode.
Setting Range
0: Red
1: Green
0: Red
2: Blue
0~ 256
0
0~ 4095
Gamma≒ 1.0
User Manual (Ver. Preliminary) - Setting List
Description
Default Value
Select the LUT channel to control.
Note: Color models only.
Set the LUT index table number.
Set the LUT value.
- 109 -