Acquisitioncontrol - IAI SW-4000TL-10GE User Manual

High speed cmos trilinear camera
Table of Contents

Advertisement

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0)

AcquisitionControl

Configure image capture settings.
Acquisition Control Item
AcquisitionMode
Acquisition Start
Acquisition Stop
Acquisition Frame Count
Acquisition Frame Rate(Hz)
AcquisitionLineRate (Hz)
Related Topic:
Variable Line Rate
Trigger Selector
Related Topic:
Image
Output Timing
TriggerMode
TriggerSource
TriggerActivation
ExposureMode
Related Topic:
Exposure Mode
Setting Range
Default
Single Frame
Multi Frame
Continuous Select the image capture mode.
Continuous
-
-
1~ 65535
-
66 ~
Acquisition Start
Acquisition End
Acquisition
Line Start
Start
Frame Start
Frame Transfer Start
Off
Off
On
PulseGenerator0 ~ 3
UserOutput0 ~ 3
Action0 ~ 3
Line4 TTL In 1
Line4 TTL
Line5 Opt In1
In1
Line10 TTL In2
Line13 TTL In3
Logical Block0 ~ 1
EncoderTrigger
Rising Edge
Falling Edge
Rising
Level High
Edge
Level Low
Off
Timed
Timed
TriggerWidth
-
Start image capture.
-
Stop image capture.
1
In MultiFrame mode, set the number of frames to capture.
66
Display the frame rate as a frequency (unit: Hz).
Set the AcquisitionLineRate (Hz). The maximum value varies
66
depending on the PixelFormat and ROI settings
Select the trigger operation.
Select the trigger mode
Select the trigger signal source.
Select the polarity of the trigger signal (i.e., location of signal at
which trigger is applied).
When TriggerSelector = LineStart,
- ExposureMode = Off or Timed: RisingEdge, FallingEdge
- ExposureMode = TriggerWidth: LevelHigh, LevelLow
Select the exposure mode.
- 71 -
Setting List (Feature Properties)
Description

Advertisement