VLT® AutomationDrive FC 302
Operating Guide
FC 302
- Mains with disconnect [mm
- Mains with fusible disconnect [mm
- Mains with contactor [mm
2
- Motor [mm
(AWG)]
Drive module power loss at 600 V [W]
Drive module power loss at 690 V [W]
Drive efficiency
(2)
Output frequency [Hz]
(4)
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
PHF overtemperature trip [°C (°F)]
Line reactor overtemperature trip [°C (°F)]
dU/dt filter overtemperature trip [°C (°F)]
Sine-wave filter overtemperature trip [°C (°F)]
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These
1
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies to dimension-
ing of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control card power
consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-efficiency-direc-
tive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each
add only 4 W.
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficien-
2
cy class, see the Ambient Conditions section. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
See also Input Power Option Losses section.
3
If using an output filter, the output frequency is limited further. See
4
Table 106: Electrical Data, Mains Supply 3x525–690 V AC
FC 302
High/normal overload
High overload=150% or 160% torque for a duration of 60 s.
Normal overload=110% torque for a duration of 60 s.
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Danfoss A/S © 2021.10
N90K
2
(AWG)]
2x95 (2x3/0 mcm)
2
(AWG)]
2x95 (2x3/0 mcm)
2
(AWG)]
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
1430
(1)(2)(3)
1480
(1)(2)(3)
0.98
0–590
110 (230)
75 (167)
145 (293)
150 (302)
150 (302)
150 (302)
N110
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
1740
1742
2101
1798
1800
2167
0.98
0–590
110 (230)
75 (167)
145 (293)
150 (302)
150 (302)
150 (302)
10.3.1 Motor Output (U, V,
W).
N200
HO
NO
160
200
250
300
200
250
D10h
253
303
380
333
242
290
Specifications
N132
N160
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2080
2649
2361
2159
2740
2446
0.98
0–590
0–590
110 (230)
110 (230)
75 (167)
75 (167)
145 (293)
145 (293)
150 (302)
150 (302)
150 (302)
150 (302)
150 (302)
150 (302)
N250
N315
HO
NO
HO
200
250
250
300
350
350
250
315
315
D10h
D10h
303
360
360
455
396
540
290
344
344
AQ262139143212en-000301 / 130R0879 | 167
3074
3175
0.98
NO
315
400
400
418
460
400