VLT® AutomationDrive FC 302
Operating Guide
Table 72: Recommended Fuse Ratings for UL Installation, 525–600 V
Drive model
Fuse P/N (Mersen)
N90K
A4J175
N110
A4J200
N132
A4J250
N160
A4J350
N200
A4J400
N250
A4J500
N315
A4J600
N355
A4J1600
N400
A4BY650
N500
A4BY750
N560
A4BY800
N630
A4BY1000
N710
A4BY1000

5.10 Enabling Motor Operation

If the status line at the bottom of the LCP reads AUTO REMOTE COAST, the unit is ready to operate but is missing an input signal
from terminal XD2.14 in the control compartment. Digital input terminal XD2.14 is designed to receive a 24 V DC external interlock
command that allows the drive to operate when using factory default programming values.
FACTORY-INSTALLED OPTIONAL EQUIPMENT
Do not remove factory-installed wiring to terminal XD2.14. If the drive does not run, refer to the documentation for the optional
equipment that is wired into terminal XD2.14.
Procedure
1.
When no interlock device is used, use a push-in type jumper (WAGO 2002-433) between terminal XD2.11 and XD2.14 in the
control compartment. This wire provides an internal 24 V signal on terminal XD2.14. The drive is ready for operation.

5.11 Selecting the Voltage/Current Input Signal

The analog input terminals XD2.7 and XD2.8 in the control compartment allow setting of input signal to voltage (0–10 V) or current
(0/4–20 mA).
Terminal XD2.7: Speed reference signal in open loop (see parameter 16-61 Terminal 53 Switch Setting).
Terminal XD2.8: Feedback signal in closed loop (see parameter 16-63 Terminal 54 Switch Setting).
Procedure
1.
Disconnect power to the drive.
2.
Remove the LCP (local control panel).
3.
Remove any optional equipment covering the switches.
110 | Danfoss A/S © 2021.10
Fuse P/N (Danfoss)
Maximum cur-
rent [A]
70CPE10971
175
70CPE10521
200
70CPE10972
250
70CPE10966
350
70CPE10522
400
70CPE10968
500
70CPE10523
600
70CPE10523
600
70CPE110003
650
70CPE10969
750
70CPE10974
800
70CPE10975
1000
70CPE10976
1100
N O T I C E
Electrical Installation
Maximum fuse
Minimum volt-
rating F1 [A]
age rating [V]
175
600
200
600
250
600
350
600
400
600
500
600
600
600
600
600
650
600
750
600
800
600
1000
600
1100
600
AQ262139143212en-000301 / 130R0879
Class F1
Class J
Class J
Class J
Class J
Class J
Class J
Class J
Class J
Class L
Class L
Class L
Class L
Class L