YASKAWA Z1000U Technical Manual page 427

Low harmonic drive bypass for hvac applications
Hide thumbs Also See for Z1000U:
Table of Contents

Advertisement

No.
L5-03
Time to Continue Making Fault Restarts
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-13
Motor Underload Protection Selection
Motor Underload Protection Level at Minimum
L6-14
Frequency
L8-02
Overheat Alarm Level
L8-05
Input Phase Loss Protection Selection
L8-06
Input Phase Loss Detection Level
L8-07
Output Phase Loss Protection
L8-09
Output Ground Fault Detection Selection
L8-38
Carrier Frequency Reduction Selection
n1-01
Hunting Prevention Selection
n1-02
Hunting Prevention Gain Setting
n3-13
Overexcitation Deceleration Gain
o1-01
Drive Mode Unit Motor Selection
o1-02
User Monitor Selection after Power Up
o1-03
Digital Operator Display Selection
o1-09
Frequency Reference Display Units
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
o2-04
Drive Model Selection
o4-03
Cooling Fan Maintenance Operation Time Setting
o4-11
UB-9 to UB-16 Initialization
o4-19
Power Unit Price
S1-01
Stillness Control Selection
S1-02
Voltage Reduction Rate
S1-03
Voltage Restoration Level
S1-04
Voltage Restoration Complete Level
S1-05
Voltage Restoration Sensitivity Time Constant
S1-06
Voltage Restoration Time Constant at Impact
S2-01
Sequence Timer 1 Start Time
S2-02
Sequence Timer 1 Stop Time
S2-03
Sequence Timer 1 Day Selection
S2-04
Sequence Timer 1 Selection
S2-05
Sequence Timer 1 Reference Source
S2-06
Sequence Timer 2 Start Time
S2-07
Sequence Timer 2 Day Selection
S2-08
Sequence Timer 2 Day Selection
S2-09
Sequence Timer 2 Selection
S2-10
Sequence Timer 2 Reference Source
S2-11
Sequence Timer 3 Start Time
S2-12
Sequence Timer 3 Stop Time
S2-13
Sequence Timer 3 Day Selection
S2-14
Sequence Timer 3 Selection
S2-15
Sequence Timer 3 Reference Source
S2-16
Sequence Timer 4 Start Time
YASKAWA SIEP YAIZ1D 01C Z1000U HVAC MATRIX Drive Bypass Technical Manual
User
Name
Setting
<1>
<1>
No.
Name
S2-17
Sequence Timer 4 Stop Time
S2-18
Sequence Timer 4 Day Selection
S2-19
Sequence Timer 4 Selection
S2-20
Sequence Timer 4 Reference Source
T1-01
Auto-Tuning Mode Selection
T1-02
Motor Rated Power
T1-03
Motor Rated Voltage
T1-04
Motor Rated Current
T1-05
Motor Base Frequency
T1-06
Number of Motor Poles
T1-07
Motor Base Speed
T1-11
Motor Iron Loss
Z1-01
Initialize
Z1-02
Password
Z1-03
Password Change
Z1-05
Auto Transfer to Bypass Upon Drive Fault
Z1-06
Power-Up Mode
Z1-07
Speed Reference Select
Z1-08
Run Command Select
Z1-09
HAND Mode Drive Speed Reference
Z1-10
Smoke Purge Preset Frequency Reference
Z1-11
2-Motor AND/OR Function Select
Z1-12
Run Delay Time
Z1-13
Pre-Interlock Run Select
Z1-14
Run Delay Frequency Reference
Z1-15
Interlock Wait Time
Z1-24
Contactor Open Delay Time
Z1-25
Contactor Close Delay Time
Z1-27
Phase Loss Brownout Voltage Level
Z1-28
Phase Loss Brownout Detection Time
H.3 User Setting Table
User
Setting
427
H