Remove The Air Baffle - HPE ProLiant ML30 Gen10 Plus Maintenance And Service Manual

Table of Contents

Advertisement

Remove the air baffle

Remove the air baffle
About this task
About this task
CAUTION:
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks
installed.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. Remove the air baffle:
a. Lift the front end of the baffle from the chassis (callout 1).
b. Remove the baffle tabs from its rear chassis slots (callout 2).
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide
41

Advertisement

Table of Contents
loading

Table of Contents