Fan replacement

Fan replacement
Subtopics
Subtopics
Removing and replacing the PCI fan
Removing and replacing the PCI fan
Removing and replacing the system fan
Removing and replacing the system fan
Removing and replacing the PCI fan
Removing and replacing the PCI fan
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
About this task
About this task
CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide