Removing And Replacing The Air Baffle - HPE ProLiant ML30 Gen10 Plus Maintenance And Service Manual

Table of Contents

Advertisement

Results
Results
To replace the component, reverse the removal procedure.

Removing and replacing the air baffle

Removing and replacing the air baffle
About this task
About this task
CAUTION:
CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks
installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide
61