CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. Disconnect the system fan cable .
7. Remove the system fan:
a. Remove the fan screws (callout 1).
b. Remove the fan from the chassis (callout 2).
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide
70