HPE ProLiant ML30 Gen10 Plus Maintenance And Service Manual page 119

Table of Contents

Advertisement

About this task
About this task
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. If installed, remove the air baffle .
7. Locate the battery on the system board .
8. If an expansion card installed on the expansion slot 2 blocks access to the system battery, remove the card.