HPE ProLiant ML30 Gen10 Plus Maintenance And Service Manual page 38

Table of Contents

Advertisement

the server from the rack.
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If installed, unlock and remove the security padlock and/or the Kensington security lock.
For more information, see the lock documentation.
5. Slide the server tray out of the rack:
a. Loosen the server tray thumbscrews (callout 1).
b. Grasp the tray notch and slide the server out of the rack (callout 2).
6. Remove the server from the tray.