44
Function Description
Table 27: "STOP" Function via Digital Inputs
No.
Event
SPL_EN is set to "1".
Setpoint value is
increased.
1
Maximum value is
achieved.
2
Set DI to "1".
3
Set DI to "0".
4
Set DI to "1".
5
Value "0" achieved.
Set DI to "0".
6
7
Maximum value is
achieved.
5.3.6
End Stop Behavior
The end stop behavior can be configured from the tab or WAGO-I/O-CHECK.
The respective parameters are described below:
Table 28: End Stop Behavior
Parameter Description
0
1
2
3
4
5
6
5.3.6.1
End Stop Behavior in "Automatic Mode"
The end stop behavior is divided into:
• Approach end stop value
• Hold current value ("Freeze")
Manual
Version 1.3.1, valid from FW/HW-Version 01/01
Hold current value.
Approach end stop value with stop ramp.
Approach end stop value with ramp 1.
Approach end stop value with ramp 2.
Approach end stop value with ramp 3.
Approach end stop value with ramp 4.
Approach end stop value with ramp 5.
WAGO I/O System 750/753
750-632 Proportional Valve Module
Description/Behavior
Present current level is maintained.
Ramp starts. Present current level is
increased.
Ramp stops. Present current level is
maintained.
Falling ramp starts. Present current level is
reduced.
Falling ramp stops.
Rising ramp starts. Present current level is
increased.
Rising ramp stops.
Falling ramp starts. Present current level is
reduced.
Ramp stops. Present current level is
maintained.
Rising ramp starts. Present current level is
increased.
Ramp stops. Present current level is
maintained.