40
Function Description
5.3.2

"Jog Mode"

In this function, the I/O module changes the setpoint value until an applied signal
is canceled. For example, a drive runs at a fixed speed in a fixed direction until a
corresponding button is released.

Figure 11: Jog Mode

Table 24: Jog Mode

No.
Event
1
Set SPL_EN to "0"
2
3
Set JOG_POS to "1"
Set JOG_POS to "0"
4
Set JOG_NEG to "1"
Set JOG_NEG to "0"
5
Set JOG_POS to "1"
Set JOG_NEG to "1"
Do not exceed minimum or maximum values!
As soon as the control value ±100 % has been achieved, no other change
occurs.
Manual
Version 1.3.1, valid from FW/HW-Version 01/01
WAGO I/O System 750/753
750-632 Proportional Valve Module
Description/Behavior
"Jog mode" is activated.
Present current level is maintained.
Present current level is increased.
Present current level is maintained.
Present current level is reduced
Present current level is maintained.
Present current level is maintained.