Sign In
Upload
Manuals
Brands
WAGO Manuals
Control Unit
750-486/040-000
User Manuals: WAGO 750-486/040-000 Channel analog input
Manuals and User Guides for WAGO 750-486/040-000 Channel analog input. We have
1
WAGO 750-486/040-000 Channel analog input manual available for free PDF download: Manual
WAGO 750-486/040-000 Manual (102 pages)
4AI 0/4-20mA NE43 Ex i XTR 4-channel analog input; 0/4...20 mA; NE43; intrinsically safe; extreme For WAGO-I/O-SYSTEM 750 XTR
Brand:
WAGO
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Notes about this Documentation
6
Validity of this Documentation
6
Copyright
6
Symbols
7
Number Notation
9
Font Conventions
9
Table 1: Number Notation
9
Table 2: Font Conventions
9
2 Important Notes
10
Legal Bases
10
Subject to Changes
10
Personnel Qualifications
10
Use of the WAGO-I/O-SYSTEM 750 in Compliance with Underlying Provisions
10
Technical Condition of Specified Devices
11
Disposal
11
Safety Advice (Precautions)
12
3 Device Description
14
Table 3: Compatibility List 750-486/040-000
15
View
17
Figure 1: View
17
Table 4: Legend for Figure "View
17
Connectors
18
Data Contacts/Local Bus
18
Figure 2: Data Contacts
18
Power Jumper Contacts/Field Supply
19
Figure 3: Power Jumper Contacts
19
Table 5: Legend for Figure "Power Jumper Contacts
19
CAGE CLAMP Connectors
20
Figure 4: CAGE CLAMP
20
Table 6: Legend for Figure "CAGE CLAMP
20
Display Elements
21
Figure 5: Display Elements
21
Operating Elements
22
Table 7: Legend for Figure "Display Elements
22
Schematic Diagram
23
Figure 6: Schematic Diagram
23
Technical Data
24
Device
24
Power Supply
24
Table 8: Technical Data - Device
24
Table 9: Technical Data - Power Supply
24
Inputs
25
Table 10: Technical Data - Inputs
25
Explosion Protection
26
Communication
26
Table 11: Technical Data - Explosion Protection
26
Table 12: Technical Data - Communication
26
Connection Type
27
Mechanical Conditions
27
Climatic Environmental Conditions
27
Table 13: Technical Data - Field Wiring
27
Table 14: Technical Data - Power Jumper Contacts
27
Table 15: Technical Data - Data Contacts
27
Table 16: Technical Data - Mechanical Conditions
27
Table 17: Technical Data - Climatic Environmental Conditions
27
Approvals
28
Standards and Guidelines
30
Table 18: Standards and Rated Conditions for Explosion Protection Applications
30
Table 20: EMC - Immunity to Interference
32
Table 21: EMC - Emission of Interference
34
Table 22: Standards and Rated Conditions for Rail Applications (en 50155)
35
4 Process Image
36
Overview
37
Table 23: Process Image - I/O Module 750-486/040-000
37
Status Bytes
38
Table 24: Status Byte CH1_S0
38
Process Data
39
Overview of Sensor Types
39
Standard Format (Two's Complement Representation)
39
Sensor Type "0-20 Ma
39
Table 25: Process Image, Sensor Type 0-20 Ma, Two's Complement Representation
39
Sensor Type "4-20 Ma
40
Table 26: Process Image, Sensor Type 4-20 Ma, Two's Complement Representation
40
Sensor Typ "3,6-21 Ma" (NAMUR NE43)
41
Table 27: Process Image, Sensor Type 3,6-21 Ma (NAMUR NE43), Two's Complement Representation
41
Special Format (Amount/Sign Format)
42
Sensor Type "0-20 Ma
42
Table 28: Process Image, Sensor Type 0-20 Ma, Amount/Sign Format
42
Sensor Type "4-20 Ma
43
Table 29: Process Image, Sensor Type 4-20 Ma, Amount/Sign Format
43
Sensor Typ "3,6-21 Ma" (NAMUR NE43)
44
Table 30: Process Image, Sensor Type 3,6-21 Ma (NAMUR NE43), Amount/Sign Format
44
5 Mounting
45
Mounting Sequence
45
Inserting and Removing Devices
46
Figure 7: Insert I/O Module (Example)
46
Inserting the I/O Module
46
Figure 8: Snap the I/O Module into Place (Example)
47
Figure 9: Removing the I/O Module (Example)
47
Removing the I/O Module
47
6 Connect Devices
48
Connecting a Conductor to the CAGE CLAMP
48
Figure 10: Connecting a Conductor to a CAGE CLAMP
48
Power Supply Concept
49
Figure 11: Ex I XTR Power Supply Concept
50
Table 31: Legend for Figure "Ex I XTR Power Supply Concept
50
Figure 12: Overvoltage Categories
51
Table 32: Legend for Figure "Overvoltage Categories
51
Supplementary Power Supply Regulations
52
Table 33: Filter Modules for 24V Power Supply
52
Figure 13: Power Supply Concept, Example 1
53
Table 34: Legend for Figure "Power Supply Concept, Example 1
53
Figure 14: Power Supply Concept, Example 2
54
Table 35: Legend for Figure "Power Supply Concept, Example 2
54
Connection Examples
55
Figure 15: Connection Example, 2-Wire Technology, Channel 1 and 4
55
Figure 16: Connection Example, 2-Wire Technology, Channel 2 and 3
55
Figure 17: Connection Example, 3-Wire Technology, Channel 1 and 4
56
Figure 18: Connection Example, 3-Wire Technology, Channel 2 and 3
56
7 Commissioning
57
Parameterization with WAGO-I/O-CHECK
57
Figure 19: WAGO-I/O-CHECK User Interface (Example)
58
Figure 20: Parameterization Dialog for the I/O Module (Example)
59
Parameterization Dialog
59
Figure 21: Title Bar in the Parameterization Dialog (Example)
60
Main Menu
60
Table 36: Buttons on the Main Menu
60
Title Bar
60
Horizontal Tab Menu
61
7.1.1.3.1 "File" Tab
61
Figure 22: Horizontal Tab Menu
61
Figure 23: Buttons in the Application Menu
61
Open" Menu Item
62
Table 37: Buttons in the Application Menu
62
Save" Menu Item
63
7.1.1.3.2 "Start" Tab
63
Figure 24: Contents of the Horizontal Tab Start
63
Figure 25: Start > Main Menu > Channel Selection List
63
7.1.1.3.3 "Connection" Tab
64
Figure 26: Connection Tab for Disconnected I/O Module
64
Figure 27: Connection Tab for Connected I/O Module
64
Figure 28: Overview of the Vertical Tab Menu
64
Vertical Tab Menu
64
7.1.1.4.1 "Module Settings" Menu Item
65
Figure 29: Module Settings Menu Item View (Example)
65
7.1.1.4.2 "Channel Settings" Menu Item
66
Table 38: Module Settings Menu Item
66
Figure 30: Channel Settings Menu Item View (Example)
67
Table 39: Channel Settings Menu Item
68
7.1.1.4.3 "Scaling" Menu Item
69
Figure 31: Scaling Menu Item View (Example)
70
7.1.1.4.4 "Calibration" Menu Item
71
Table 40: Scaling Menu Item
71
Figure 32: Calibration Menu Item View (Example)
72
Table 41: Calibration Menu Item
73
7.1.1.4.5 "Monitoring" Menu Item
74
Figure 33: Monitoring Menu Item View (Example)
74
7.1.1.4.6 "Information" Menu Item
75
Table 42: Monitoring Menu Item
75
Application Area
76
Figure 34: Information Menu Item View (Example)
76
Figure 35: Expanding the Status Messages Window
76
Status Messages
76
Figure 36: Status Messages in the Application Window of the Parameterization Dialog
77
Figure 37: Status Bar in the Parameterization Dialog
77
Status Bar
77
Table 43: Status Messages - Possible Status Messages with Additional Information
77
Calibrating Measured Values
78
Table 44: Sensor Types
78
Table 45: Variable Legend - Calibrating Measured Values
78
Example of Determining Gain and Offset
79
Scaling Measured Values
80
Table 46: Variable Legend - Scaling Measured Values
80
8 Diagnostics
81
I/O Module Behavior in the Event of an Error
81
Table 47: Priority Levels of Diagnostic Functions
81
Table 48: Behavior in the Event of an I/O Module Error Dependent on the Configuration
82
9 Use in Hazardous Environments
84
Marking Configuration Examples
85
Figure 38: Marking Example According to ATEX and Iecex
85
Figure 39: Text Detail - Marking Example According to ATEX and Iecex
85
Marking for Europe According to ATEX and Iecex
85
Table 49: Description of Marking Example According to ATEX and Iecex
86
Figure 40: Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
87
Figure 41: Text Detail - Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
87
Table 50: Description of Marking Example for Approved Ex I I/O Module According to ATEX and Iecex
88
Figure 42: Marking Example According to NEC
89
Figure 43: Text Detail - Marking Example According to NEC 500
89
Marking for America (NEC) and Canada (CEC)
89
Table 51: Description of Marking Example According to NEC 500
89
Table 52: Description of Marking Example for Approved Ex I I/O Module
90
Table 53: Description of Marking Example for Approved Ex I I/O Modules
90
Table 54: Description of Marking Example for Approved Ex I I/O Modules
91
Installation Regulations
92
Special Notes Regarding Explosion Protection
92
Special Notes Regarding ANSI/ISA Ex
94
10 Appendix
95
Configuration and Parameterization Via GSD for PROFIBUS DP and PROFINET IO
95
Configuration 4AI 0/4-20 Ma Ex I (NAMUR)
95
PROFIBUS DP Fieldbus Coupler 750-333/040-000
95
Parameterization 4AI 0/4-20 Ma Ex I (NAMUR)
95
Table 55: Configuration PROFIBUS DP
95
PROFIBUS DP Fieldbus Coupler 750-333/040-000
96
Table 57: General Module / Channel Parameters
96
List of Figures
97
List of Tables
99
Advertisement
Advertisement
Related Products
WAGO 750-486
WAGO 750-489
WAGO 750-481/040-000
WAGO 750-483/040-000
WAGO 750-482/000-001
WAGO 750-482
WAGO 750-469/040-000
WAGO 750-492/040-001
WAGO 750-469/000-008
WAGO 750-469/003-000
WAGO Categories
I/O Systems
Control Unit
Power Supply
Switch
Controller
More WAGO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL