Undervoltage, Short Circuit, Wire Break, Overtemperature; Undervoltage; Figure 53: Response During Undervoltage - WAGO 750-632 Manual

Proportional valve module wago i/o system 750/753
Hide thumbs Also See for 750-632:
Table of Contents

Advertisement

WAGO I/O System 750/753
750-632 Proportional Valve Module
10.5
Undervoltage, Short Circuit, Wire Break,
Overtemperature
10.5.1

Undervoltage

As soon as a undervoltage occurs, the output stage is automatically switched off.
The LEDs for "Status channel A", "Status channel B", and "General I/O module
error" light up red. The status bit READY is set to "0". The status bits 0 and 6 of
the local bus are set to "1". The subsequent figure clarifies the behavior:

Figure 53: Response During Undervoltage

Version 1.3.1, valid from FW/HW-Version 01/01
Diagnostics 101
Manual