Details of remote registers
Bridge module status area (RWr0)
This area is used to check the status of the NZ2GN-GFB.
RWr0
b0 to b8
b9
b10
b11
b12 to b15
■Operation condition setting completion flag (RWr0.b9)
This flag is used to change the parameters of the NZ2GN-GFB using the program.
The parameter is saved to the non-volatile memory of NZ2GN-GFB by writing parameter data to the remote buffer memory
with the program, and then turning on the 'Operation condition setting request flag' (RWw0.b9).
Once the parameter is saved, the flag changes from off to on.
The parameter saved to the non-volatile memory is reflected when the NZ2GN-GFB is restarted, so power off and on the
system or reset it.
In addition, if the module is in error state, turning on the 'Operation condition setting request flag' (RWw0.b9) clears the error
through the same process as when the 'Error clear request flag' (RWw0.b10) is turned on.
• For the case where data link is established at the turning on of the module power supply
Module power supply
'Operation condition setting
completion flag' (RWr0.b9)
'Operation condition setting
request flag' (RWw0.b9)
Operation parameter/monitor area
Parameter area
Non-volatile memory
'Remote READY' (RWr0.b11)
Remote I/O control status
Executed by the NZ2GN-GFB
Executed by the program
(1) The setting value is changed.
(2) The I/O module starts operating with setting value A.
(3) The I/O module starts operating with setting value B.
Name
Use prohibited
Operation condition setting completion flag
Use prohibited
Remote READY
Use prohibited
ON
OFF
OFF
OFF
Setting value A
Setting value A
Setting value A
(2)
ON
OFF
Control stopped
Control performed
ON
ON
(1)
Setting value B
(2)
Control
Control
stopped
performed
Setting value B
Setting value B
Setting value B
(3)
Control
Control stopped
performed