4.
Set the refresh settings as follows.
[Navigation window] [Parameter] [Module Information] [RJ71GF11-T2] [Basic Settings] [Refresh Settings]
[Detailed Setting]
5.
Display the CC-Link IE Field configuration window and register a general local station.
[Navigation window] [Parameter] [Module Information] [RJ71GF11-T2] [Basic Settings] [Network
Configuration Settings] [Detailed Setting]
6.
Set the following parameters for the general local station.
Setting item
RX/RY Setting
RWw/RWr Setting
7.
Click the [Close with Reflecting the Setting] button to close the "CC-Link IE Field Configuration" window.
8.
Click the [Apply] button.
9.
Write the set parameters to the CPU module of the CC-Link IE Field Network master station. Then, reset the CPU
module or power off and on the system.
[Online] [Write to PLC]
10.
Set the CPU module of the CC-Link IE Field Network master station to RUN, and check that the D LINK LED (CC-Link IE
Field) of the NZ2GN-GFB is turned on.
In the program example, default values are used for parameters that are not shown above. For the
parameters, refer to the following.
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
8 PROGRAMMING
114
8.2 Program Examples
Points
Start
End
Points
Start
End
Description
32
0000
001F
16
0000
000F