Error Code List - Mitsubishi Electric CC-Link IE TSN User Manual

Field network bridge module
Table of Contents

Advertisement

10.7

Error Code List

The error codes are classified into the following three types.
Classification
Major error
Moderate error
Minor error
This sections describes the error codes of the NZ2GN-GFB.
Error codes that can be checked using CC-Link IE TSN/CC-Link IE Field diagnostics
The following table shows the error codes that can be checked with "Error history/event history" of CC-Link IE TSN/CC-Link IE
Field diagnostics.
( Page 148 Checking Event Codes and Error Codes)
Error code
Error type
0010H
Major error
0105H
Moderate
error
0106H
Moderate
error
0108H
Moderate
error
010AH
Moderate
error
0112H
Moderate
error
0113H
Moderate
error
10 TROUBLESHOOTING
152
10.7 Error Code List
Description
An error that cannot be recovered. The RUN LED turns off.
An error where the module cannot continue to operate. The ERR. LED flashes.
An error where the module can continue to operate. The ERR. LED turns on.
Error name
Error definition and causes
Hardware error
Module hardware error
Non-volatile memory
The IP address and subnet mask stored
data error (IP address)
in the non-volatile memory are
abnormal.
CC-Link IE TSN IP
The CC-Link IE TSN IP address setting
address setting switch
switches are set to 255.
out of range error
Non-volatile memory
The parameter data stored in the non-
data error (parameter)
volatile memory are abnormal.
Non-volatile memory
The module parameters cannot be
access error (module
saved because an error in access to the
parameter)
non-volatile memory was detected.
Non-volatile memory
The F/W update information stored in
data error (F/W update
the non-volatile memory is faulty.
information)
CC-Link IE Field
The CC-Link IE Field Network station
Network station
number setting switch is set to
number setting switch
something other than 0.
out of range error
(Master station)
Action
• Power off and on the NZ2GN-GFB.
• If this error occurs again, the possible cause is a
module failure. Please consult your local Mitsubishi
representative.
• The module will be automatically recovered
immediately after the error occurs. However, the stored
IP address and subnet mask are lost, and operation is
performed assuming that the following are stored.
IP address: 192.168.3.250
Subnet mask: 255.255.255.0
• Take measures against noise with a shielded cable for
connection.
• If this error occurs again, the possible cause is a
module failure. Please consult your local Mitsubishi
representative.
Turn on the power supply with the CC-Link IE TSN IP
address setting switches set to a value in the range 0 to
254.
• Change the 'Parameter area initialization command'
(1002H) from Off (no command) to On (Command) to
Off (no command), then turn off and on the NZ2GN-
GFB or reset the non-volatile memory parameters to
their default values. After that, set the parameters
again.
• Take measures against noise with a shielded cable for
connection.
• If this error occurs again, the possible cause is a
module failure. Please consult your local Mitsubishi
representative.
• The module parameters are not saved in the non-
volatile memory.
• Take measures against noise with a shielded cable for
connection.
• If this error occurs again, the possible cause is a
module failure. Please consult your local Mitsubishi
representative.
• Update the F/W of the NZ2GN-GFB using the F/W
update function.
• Take measures against noise with a shielded cable for
connection.
• If this error occurs again, the possible cause is a
module failure. Please consult your local Mitsubishi
representative.
Take any of the following actions, and then turn off and on
the NZ2GN-GFB or perform reset.
• Set the CC-Link IE Field Network station number
setting switch to 0.
• Set "Station-specific mode setting" to "Local station"
and then set the module parameters.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc-link ie