Parameter error status of each station (2017H.b0)
Stores the parameter error status of each station.
• Off: All stations normal
• On: Faulty station exists
If this relay is turned on, the status of each station can be checked with 'Parameter error status of each station' (3170H to
3177H).
Depending on the update timing, 'Parameter error status of each station' (3170H to 3177H) may not be updated immediately.
Condition
• Enabled when 'Baton pass status of own station' (2004H.b7) is off. When 'Baton pass status of own station' (2004H.b7) is turned on (error), data from
immediately before the error is held.
• Reserved stations and stations higher than the maximum station number are ignored.
Reserved station function disable status (2018H.b0)
Stores whether there is a station whose reserved station setting is temporarily canceled.
• Off: Not exist
• On: Exists
If this relay is turned on, the status of each station can be checked with 'Reserved station function disable status' (3180H to
3187H).
Depending on the update timing, 'Reserved station function disable status' (3180H to 3187H) may not be updated
immediately.
Condition
Enabled when 'Baton pass status of own station' (2004H.b7) is off. When 'Baton pass status of own station' (2004H.b7) is turned on (error), data from
immediately before the error is held.
APPX
240
Appendix 3 Remote Buffer Memory