Mitsubishi Electric CC-Link IE TSN User Manual page 105

Field network bridge module
Table of Contents

Advertisement

4.
Set the refresh settings as follows.
[Navigation window]  [Parameter]  [Module Information]  [RJ71GN11-T2]  [Basic Settings]  [Refresh Settings]
 [Detailed Setting]
5.
Display the CC-Link IE TSN configuration window and add the NZ2GN-GFB.
[Navigation window]  [Parameter]  [Module Information]  [RJ71GN11-T2]  [Basic Settings]  [Network
Configuration Settings]  [Detailed Setting]
6.
Set "Station-specific mode setting" to "Master Station".
7.
Set the following parameters for the NZ2GN-GFB.
Setting item
RX Setting
RY Setting
RWr Setting
RWw Setting
8.
Click the [Close with Reflecting the Setting] button to close the "CC-Link IE TSN Configuration" window.
9.
Click the [Apply] button.
10.
Write the set parameters to the CPU module on the CC-Link IE TSN master station. Then, reset the CPU module or
power off and on the system.
[Online]  [Write to PLC]
Points
Start
End
Points
Start
End
Description
48
0000
002F
64
0000
003F
8 PROGRAMMING
103
8.2 Program Examples