Precautions
• If the NZ2GN-GFB is not turned off and on or reset, the system runs using the old parameters.
• Invalid parameters are not saved in the non-volatile memory. Check the event history after writing parameters. If
"Parameter read" is performed after writing an invalid parameter, the invalid parameter is read instead of the parameter
saved in the non-volatile memory.
• When setting parameters using device station parameter processing, do not perform parameter automatic setting. When
device station parameter processing is executed after performing parameter automatic setting, the parameters in the
NZ2GN-GFB are changed into the parameters set using device station parameter processing. However, when the NZ2GN-
GFB is turned off or disconnected and data link is executed again after that, the parameters in the non-volatile memory in
the NZ2GN-GFB are overwritten by the parameters set using parameter automatic setting.
6 PARAMETER SETTINGS
6.3 Module Parameter Setting
6
65