Common Parameters - Mitsubishi Electric FATEC MELSEC iQ-R Training Manual

Table of Contents

Advertisement

4.3

Common Parameters

Parameters
[Pr.24]
[Pr.82]
[Pr.89]
[Pr.96]
[Pr.97]
[Pr.150]
[Pr.151]
[Pr.152]
[Pr.153]
Item
Manual pulse generator/
Incremental synchronous encoder
input selection
Forced stop valid/invalid selection
Manual pulse generator/
Incremental synchronous encoder
input type selection
Operation cycle setting
SSCNET setting
Input terminal logic selection
Manual pulse generator/
Incremental synchronous encoder
input logic selection
Maximum number of control axes
External input signal digital filter
setting
Setting value, setting range
0: A-phase/B-phase multiplied by 4
1: A-phase/B-phase multiplied by 2
2: A-phase/B-phase multiplied by 1
3: PULSE/SIGN
0: Valid (External input signal)
1: Invalid
2: Valid (Buffer memory)
0: Differential output type
1: Voltage output/open collector type
0000H: 0.888 ms
0001H: 1.777 ms
0002H: 3.555 ms
0200H: 0.444 ms
FFFFH: Automatic setting
0: SSCNET III
1: SSCNET III/H
b0: SIN1
to
b19: SIN20
0: Negative logic
1: Positive logic
0: No setting
1 to 16: Maximum number of control
axes
0H: 3.2 ms
1H: 2.4 ms
2H: 1.6 ms
3H: 1.2 ms
4H: 0.8 ms
5H: 0.4 ms
6H: 0.2 ms
4-5
Default
value
FFFFH
0: ON at leading
edge
1: ON at trailing
edge
6666H
0
0
1
1
0
0
0