HARDWARE MANUAL
FX
-32DP-IF Profibus-DP Interface Unit
2N

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MELSEC FX2N-32DP-IF

  • Page 1 HARDWARE MANUAL -32DP-IF Profibus-DP Interface Unit...
  • Page 2 • If in doubt about operation or use of the FX -32DP-IF Profibus-DP Interface Unit please consult the nearest Mitsubishi Electric distributor. • This manual is subject to change without notice.
  • Page 3 FX2N-32DP-IF Profibus-DP Interface Unit -32DP-IF Profibus-DP Interface Unit Manual number : JY992D77101 Manual revision : E Hardware Manual Date : November 2008...
  • Page 4 FX2N-32DP-IF Profibus-DP Interface Unit...
  • Page 5 FX2N-32DP-IF Profibus-DP Interface Unit Guidelines for the Safety of the User and Protection of the FX -32DP-IF Profibus-DP Interface Unit. This manual provides information for the use of the FX -32DP-IF Profibus-DP Interface Unit. The manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows: a) Any engineer who is responsible for the planning, design and construction of automatic equipment using the product associated with this manual, should be of a competent...
  • Page 6 FX2N-32DP-IF Profibus-DP Interface Unit Note’s on the Symbols Used in this Manual At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of the equipment.
  • Page 7 FX2N-32DP-IF Profibus-DP Interface Unit • Under no circumstances will Mitsubishi Electric be liable responsible for any consequential damage that may arise as a result of the installation or use of this equipment. • All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation.
  • Page 8 FX2N-32DP-IF Profibus-DP Interface Unit...
  • Page 9: Table Of Contents

    FX2N-32DP-IF Profibus-DP Interface Unit Table of Contents Safety Guidelines ................iii 1. Introduction....................1-1 1.1 Features of the 32DP-IF ..................1-1 1.2 External Dimensions and Each Part Name ............1-2 1.2.1 Pin Configuration ....................... 1-4 1.3 System Configuration ..................1-5 1.3.1 Connected Monitoring Tools ..................1-6 1.3.2 Connected Extension Blocks and Units ..............
  • Page 10 FX2N-32DP-IF Profibus-DP Interface Unit 3. Specifications ..................3-1 3.1 General Specifications..................3-1 3.2 Power Supply Specifications ................3-2 3.3 Performance Specifications ................. 3-3 4. Address Setting ..................4-1 4.1 Setting the Address ..................... 4-1 4.2 Example Address Setting ..................4-2 5. Diagnostics....................5-1 5.1 Preliminary Checks....................
  • Page 11: Introduction

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 Introduction The FX -32DP-IF(-D) Profibus-DP Interface Unit (called “32DP-IF” hereinafter) can be used to connect FX series extension units/blocks and special function units/blocks directly to an existing Profibus-DP network. The 32DP-IF provides an intelligent slave function for decentralized control applications. Digital and analog data from a Profibus-DP master CPU (called “DP-master”...
  • Page 12: External Dimensions And Each Part Name

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 External Dimensions and Each Part Name Dimensions: mm (inches) Accessory: GSD files (FD: 1 piece) MASS (Weight): Approx. 0.4 kg (0.88 lbs) Figure 1.1: External Dimensions - 3 2 D P - I F ( A C P o w e r S u p p l y T y p e ) - 3 2 D P - I F - D ( D C P o w e r S u p p l y T y p e ) C O M 2 4 +...
  • Page 13 FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 a) Profibus-DP communication port (D-SUB 9 pin) b) Power supply terminals (screw terminal: M3.5 (0.14")) -32DP-IF (AC power supply type): L, N and grounding terminal -32DP-IF-D (DC power supply type): 24+, 24- and grounding terminal c) Direct mounting hole (2-φ4.5 (0.18")) d) 24 V DC power terminal (screw terminal: M3.5 (0.14")) -32DP-IF-D does not have this terminal.
  • Page 14: Pin Configuration

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 1.2.1 Pin Configuration The connector is a 9-pin D-SUB type and the pin configuration is shown below. Figure 1.2: Pin Layout 9-pin D-SUB Table 1.1: Pin Configuration Connector Signal Meaning RXD/TXD-P Receive/transmit-Data-P Request to send DGND Data Ground Voltage-Plus...
  • Page 15: System Configuration

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 System Configuration Figure 1.3: System Configuration Profibus-DP network DP-master Slave or Slave or DP-master * DP-master * Extension I/O units/blocks and -32DP-IF Profibus-DP special function blocks * interface unit * *1 The units at each end of the Profibus-DP network must have a terminating resistor. This will either be in the master, slave unit or in the Profibus connector.
  • Page 16: Connected Monitoring Tools

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 1.3.1 Connected Monitoring Tools An FX-20P-E or personal computer can be used to monitor the 32DP-IF and the data exchanged with the Profibus. For operating instructions of the FX-20P-E or personal computer, refer to their respective operation manuals. For device numbers and explanation, refer to the -32DP-IF User’s Manual.
  • Page 17: Connected Extension Blocks And Units

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 1.3.2 Connected Extension Blocks and Units Table 1.3: Extension I/O Blocks/Units and Special Function Blocks Supported Unit Type Type Name Version -32ER-ES/UL, FX -32ET-ESS/UL, Model: V1.00 ∼ -48ER-ES/UL, FX -48ET-ESS/UL GSD file:V1.00 ∼ Extension Units -48ER-UA1/UL (Digital I/O Units) Model: V2.10 ∼...
  • Page 18: Configuration Rules Reference

    FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 1.3.3 Configuration Rules Reference Further information for the Configuration Rules can be found in FX -32DP-IF User’s Manual. 1) Total I/O points on the system ≤ 256 points The following (a ~ c) I/O points must be a total of 256 points or less. For I/O point allocation for each extension unit/block and each special function unit/block, refer to FX -32DP-IF User’s Manual.
  • Page 19 FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 4) Total user parameter length ≤ 193 bytes (or DP master’s maximum user parameter length if ≤ 193 bytes) The user parameter length must be a total of 193 bytes (or DP master’s maximum exchange data length if ≤...
  • Page 20 FX2N-32DP-IF Profibus-DP Interface Unit Introduction 1 MEMO 1-10...
  • Page 21: Mounting And Wiring

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Mounting and Wiring Mounting 2.1.1 Mounting Arrangements To prevent a rise in temperature, mount the units to the back walls. Never mount them to the floor, ceiling or side wall of an enclosure. Figure 2.1: Mounting Location >...
  • Page 22 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.2: Mounting Arrangement...
  • Page 23: Mounting

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 2.1.2 Mounting Mounting method for the 32DP-IF is DIN rail mounting or direct wall mounting. 1) DIN Rail Mounting - Align the upper side of the DIN rail mounting groove of the 32DP-IF with a DIN rail*1 ( ), and push it on the DIN rail( ).
  • Page 24 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.4: Remove from DIN Rail „ ƒ *1 Uses DIN 46277 <35mm (1.38")> 2) Direct Mounting to Back Walls The 32DP-IF can be mounted with M4 screws by using the direct mounting holes. An interval space between each unit of 1 ~ 2 mm is necessary.
  • Page 25: Caution For Wiring

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Caution for Wiring 1) Do not lay signal cable near to either high voltage power cabling or cabinet housing along the same trunking duct. Effects of noise or surge induction may occur. Keep signal cables of more than 100 mm (3.94") from these power cables.
  • Page 26 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 9) The terminal tightening torque is 0.5 to 0.8 N•m. Tighten securely to avoid malfunction. 10)The terminal screws of FX -32DP-IF is M3.5 (0.14"). However, the terminal screws of the , FX Series extension I/O units/blocks and special function units/blocks are M3 (0.12").
  • Page 27 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 a) Handle the crimp terminal of the following size as and when 1 wire is used per terminal. Refer to Figure 3.3 for installation instructions. Figure 2.5: Crimp Terminal for M3.5 Screws φ...
  • Page 28 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 b) Handle the crimp terminal of the following size as and when 2 wires are used per terminal. Refer to Figure 3.6 for installation instructions. Figure 2.8: Crimp Terminal for M3.5 Screws φ...
  • Page 29: Power Supply

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Power Supply Further information for the extension unit’s wiring can be found in the FX Series Hardware Manual. Further information for special function units/blocks can be found in their respective manual. For wiring of grounding, refer to Section 2.4.
  • Page 30: Ac Power Supply Type: Fx 2N -32Dp-If

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 2.3.1 AC Power Supply Type: FX -32DP-IF When wiring a 32DP-IF and extension I/O units/blocks, the connection method is identical to a series PLC. Further information can be found in the FX -32DP-IF User’s Manual and Series Hardware Manual.
  • Page 31 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.11:AC Power Supply Type: FX -32DP-IF Grounding Ref. Section 2.4 100~ Service power supply Service power supply 240V Fuse Emegency Start stop Switch Switch Extension Extension I/O Unit I/O Block <AC Power (Source Supply Type>...
  • Page 32: Dc Power Supply Type: Fx 2N -32Dp-If-D

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 2.3.2 DC Power Supply Type: FX -32DP-IF-D When wiring a 32DP-IF and extension I/O units/blocks, the connection method is identical to a series PLC. Further information can be found in the FX -32DP-IF User’s Manual and Series Hardware Manual.
  • Page 33 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.12:DC Power Supply Type: FX -32DP-IF-D Fuse Grounding Ref. Section 2.4 Emegency Start stop Switch Switch Extension Extension I/O Unit I/O Block <DC Power (Source Supply Type> -32DP-IF-D Input) (Source Input Relay Output) Power supply for AC loads Power supply for DC loads...
  • Page 34: Profibus-Dp Network

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Profibus-DP Network To connect the 32DP-IF to a Profibus-DP network should be used only the Profibus connectors and shielded twisted-pair cable complying with EN50170. Please use terminating resistors and Profibus connectors as shown in the DP-master manual and Profibus connector manual.
  • Page 35 FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.13:Connect to Profibus-DP Network 32DP-IF L(24+) N(24 Table 2.1: Connect to Profibus-DP Network Ref. Description ① Power source for 32DP-IF (Refer to section 3.2) ② Grounding terminal in 32DP-IF ③ Profibus connector (Refer to Figure 3.10) ④...
  • Page 36: Wiring For Connecting To Extension Blocks/Units And Special Function Blocks

    FX2N-32DP-IF Profibus-DP Interface Unit Mounting and Wiring 2 Figure 2.14:Profibus Connection S hielded tw isted-pair cable to P rofibus-D P netw ork -32D P -IF P rofibus-D P Interface U nit Wiring for Connecting to Extension Blocks/Units and Special Function Blocks Further information can be found in FX -32DP-IF User’s Manual, FX Hardware Manual and...
  • Page 37: Specifications

    FX2N-32DP-IF Profibus-DP Interface Unit Specifications 3 Specifications General Specifications Table 3.1: General Specifications Item Description Operating Temperature 0 ~ 55°C (32 to 131°F) Storage Temperature -20 ~ 70°C (-4 to 158°F) Operating Humidity 35 ~ 85% Relative Humidity, No condensation Storage Humidity 35 ~ 90% Relative Humidity, No condensation 10 ~ 57Hz: 0.075mm Half Amplitude...
  • Page 38: Power Supply Specifications

    FX2N-32DP-IF Profibus-DP Interface Unit Specifications 3 Power Supply Specifications Table 3.2: Power Supply Specifications Description Item -32DP-IF -32DP-IF-D (AC Power Supply Type) (DC Power Supply Type) 100 ~ 240 V AC +10% -15%, Power Supply 24 V DC +20% -30% 50/60 Hz 10 ms at 100 V AC 5 ms at 24 V DC...
  • Page 39: Performance Specifications

    FX2N-32DP-IF Profibus-DP Interface Unit Specifications 3 Performance Specifications Table 3.3: Performance Specifications Items Specifications Maximum Number of Controllable Maximum 256 points (see section 1.3) I/O Points Transmission data Max.200 bytes, total of sent and received during one bus cycle. (Exchange data length) (input: Max.
  • Page 40 FX2N-32DP-IF Profibus-DP Interface Unit Specifications 3 MEMO...
  • Page 41: Address Setting

    FX2N-32DP-IF Profibus-DP Interface Unit Address Setting 4 Address Setting Setting the Address The slave address of 32DP-IF for Profibus network is set by the ON/OFF configuration of DIP switches. Slave address setting range is 0 ~ 126. When 32DP-IF’s power supply is turned ON, the slave address is the sum total of these DIP switch values.
  • Page 42: Example Address Setting

    FX2N-32DP-IF Profibus-DP Interface Unit Address Setting 4 Example Address Setting If slave address of 32DP-IF is set to “22”, the DIP switches are as shown below. Figure 4.2: Address Setting...
  • Page 43: Diagnostics

    FX2N-32DP-IF Profibus-DP Interface Unit Diagnostics 5 Diagnostics Preliminary Checks 1) Check “POWER LED”. If this is OFF, please see section 5.2. 2) Check that the slave address is the same at the 32DP-IF and the DP-master configuration. If the slave address is not the same in the 32DP-IF and in the DP-master, change this address to match in both modules.
  • Page 44: Check The Status Of The Leds Of The 32Dp-If

    FX2N-32DP-IF Profibus-DP Interface Unit Diagnostics 5 Check the Status of the LEDs of the 32DP-IF If the 32DP-IF does not seem to operate normally, check the following items. For error flags, error codes, and device explanation, refer to FX -32DP-IF User’s Manual. 1) Check the status of the “POWER LED”.
  • Page 45 FX2N-32DP-IF Profibus-DP Interface Unit Diagnostics 5 3) Check the status of the “BF LED” Table 5.3: BF LED Check Status Description Check D8024. If D8024 does not show a stable baud rate (i.e. always changing) then check DP-network cables. Check M8004. If M8004 is ON, refer to FX -32DP-IF User’s Manual.
  • Page 46 FX2N-32DP-IF Profibus-DP Interface Unit Diagnostics 5 MEMO...
  • Page 47: Further Information Manual Lists

    FX2N-32DP-IF Profibus-DP Interface Unit Appendix A: Appendix A: Further Information Manual Lists Table A-1: Further Information Manual Lists Manual name Manual No. Description Series This manual contains explanations for wiring, Programmable Controllers JY992D66301 installation and specification, etc. about FX Series Hardware Manual programmable controller.
  • Page 48 FX2N-32DP-IF Profibus-DP Interface Unit Appendix A: Table A-1: Further Information Manual Lists Manual name Manual No. Description -4DA This manual contains explanations for wiring, Special Function Block JY992D65901 installation, specification and BFM allocation, etc. User’s Guide about FX -4DA special function block. -4AD This manual contains explanations for wiring, Special Function Block...
  • Page 49 FX2N-32DP-IF Profibus-DP Interface Unit Appendix A: Table A-1: Further Information Manual Lists Manual name Manual No. Description This manual contains explanations for specification about FX -20GM Positioning Control Unit. -20GM User’s Guide JY992D77601 However, the user’s guide’s text is already contained in the hardware/programming manual.
  • Page 50 FX2N-32DP-IF Profibus-DP Interface Unit Appendix A: Table A-1: Further Information Manual Lists Manual name Manual No. Description This manual contains explanation for wiring, -10PG JY992D85801 installation, specification and BFM allocation, etc. User’s Manual about the FX -10PG Pulse Generation Unit. This manual contains explanations for N:N network, FX Communication parallel link and computer link no protocol...
  • Page 51: Update History Of Fx 2N -32Dp-If And Gsd File

    FX2N-32DP-IF Profibus-DP Interface Unit Appendix B: Appendix B: Update History of FX -32DP-IF and GSD File Table B-1: Update History of FX -32DP-IF and GSD File Version Contents 32DP-IF GSD File Hardware First Product Supports the following unit / block. •...
  • Page 52 FX2N-32DP-IF Profibus-DP Interface Unit Appendix B: Table B-1: Update History of FX -32DP-IF and GSD File Version Contents 32DP-IF GSD File Hardware Supports the swap parameter (Second byte bit 4 in the global user V2.00 V2.00 parameter). (Further infromation can be found in the FX -32DP-IF User’s Manual.) Supports the following •...
  • Page 54 HARDWARE MANUAL -32DP-IF Profibus-DP Interface Unit HEAD OFFICE: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN HIMEJI WORKS: 840, CHIYODA CHO, HIMEJI, JAPAN Effective Nov. 2008 JY992D77101E Specification are subject (MEE) to change without notice.