Parameters
[PA24]
Function selection A-4
One-touch tuning - Overshoot
[PA25]
permissible level
[PA26]
Function selection A-5
*1. The parameters will be enabled by once turning off the servo amplifier power supply and reapplying the
power after changing the parameters (transmitting the parameters from RD77MS to the servo amplifier).
*2. The parameters will be enabled by once turning off the servo amplifier power supply and reapplying the
power or resetting the controller after changing the parameters (transmitting the parameters from
RD77MS to the servo amplifier).
[PA01] Operation mode
Select a operation mode.
0
0
Compatibility mode setting
[PA02] Regenerative option
Used to select the regenerative option.
0 0
*.
Input the set value in
[PA03] Absolute position detection system
Determine whether or not the absolute position detection system will be used.
[PA04] Function selection A-1
This is used to select the forced stop input and forced stop deceleration function.
0 0
Servo forced stop selection
Forced stop deceleration function selection
Item
0: Standard mode
1: 3 inertia mode
2: Low response mode
0 to 100 [%]
0: Disable
*2
1: Enable
H
Operation mode setting
H
Regenerative option selection
(hexadecimal).
H
Setting range
4-38
Default
value
0
0
0