Mitsubishi Electric FX2N-10GM User Manual

Melsec-f fx2n
Hide thumbs Also See for FX2N-10GM:

Advertisement

Quick Links

This manual only describes the specifications for FX
For complete operation, wiring, mounting and programming instructions please refer to the FX
-20GM HARDWARE PROGRAMMING MANUAL, FX PROGRAMMING MANUAL ΙΙ and FX SERIES
FX
2N
HARDWARE MANUAL.
These manuals should be read and understood before attempting to install or use the unit.
And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always
forward it to the end user.
Safety Precaution
This manual classifies the safety precautions into two categories:
Indicates that incorrect handling may cause hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
It is important to follow all precautions for personal safety
DESIGN PRECAUTIONS
Install a safety circuit outside the PLC so that the entire system conservatively operates even if an
abnormality occurs in the external power supply or a failure occurs in the PLC.
If the safety circuit is installed inside the PLC, malfunction and erroneous output may cause
accidents.
STARTUP AND MAINTENANCE
PRECAUTIONS
Do not touch any terminal while the FX
Doing so may cause electric shock or malfunctions.
Before cleaning or retightening terminals externally cut off all phases of the power supply.
Failure to do so may cause electric shock.
Thoroughly read the manual, sufficiently confirming safety, then perform returning to the zero point
in the MANU/AUTO mode, jog operation, step operation or automatic operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND MAINTENANCE
PRECAUTIONS
Do not disassemble or modify the FX
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric distributor.
Turn off the power to the FX
extension cable.
Failure to do so may cause equipment failures or malfunctions.
Turn off the power to the FX
following devices.
Failure to do so may cause equipment failures or malfunctions.
-
Peripheral devices, FX Series terminal blocks
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the environmentally safe recycling
and disposal of your device.
(Read these precautions before use.)
2N
-10GM positioning controller before connecting or disconnecting any
2N
-10GM positioning controller before attaching or detaching the
2N
FX
USER'S GUIDE
-10GM positioning controller.
2N
-10GM positioning controller's power is on.
2N
-10GM positioning controller.
-10GM
2N
JY992D77701J
and
may also cause severe injury.
-10GM,
2N
.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric FX2N-10GM

  • Page 1 Do not disassemble or modify the FX -10GM positioning controller. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric distributor. • Turn off the power to the FX -10GM positioning controller before connecting or disconnecting any extension cable.
  • Page 2: External Dimensions

    TRANSPORTATION AND STORAGE PRECAUTIONS • The product is a precision instrument. During transportation, avoid impacts larger than those specified in Section 5.2 by using dedicated packaging boxes and shock-absorbing palettes. Failure to do so may cause failures in the product. After transportation, verify operation of the product and check for damage of the mounting part, etc.
  • Page 3: Product Composition

    4. Product composition 4.1 Each part name The name and description of each part of the FX -10GM are explained below. ➀ Operation indicator LED ➁ MANU/AUTO switch ➂ Connector for programming tool ➃ I/O display ➄ Connector for PLC extension block ➅...
  • Page 4: Power Supply Specification

    5. Specification 5.1 Power supply specification Item Contents Power supply DC24V +10%, -15% Allowance power The operation is continued to the momentary power failure is 5ms or less. failure time Power consumption Fuse 125V 1A 5.2 General specifications Item Contents 0 to 55 °C (operation).
  • Page 5: Input Specifications

    5.4 Input specifications Input from general-purpose Item Input from drive unit equipment Group 1 START, STOP , ZRN, FWD, RVS, LSF, LSR SVRDY, SVEND Group 2 DOG Input signal General-purpose input, interruption input: name Group 3 X0 to X3 Group 4 Manual pulse generator Circuit insulation By photocoupler By photocoupler...
  • Page 6 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 7 Do not disassemble or modify the FX -10GM positioning controller. Dimensions mm(inch) the external power supply fails. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric distributor. 3 Ground Red + • Turn off the power to the FX...
  • Page 8 20mA or less Item Contents This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any Open circuit leak Number of control 0.1mA 24V DC or less 0.1mA/24V DC or less...

Table of Contents