5. To re-install, follow these steps in reverse order.
Route the douser motor harness through the clips running along the projector frame to prevent
it from falling into the lamp area.
6. Perform LampLOC

Igniter

The igniter is located below the UV filter directly in front of the lamp with a plastic white shield
covering it for protection. The main blower helps keep the igniter cool.
Warning! If not avoided, the following could result in death or serious injury.
This procedure must be performed by Christie qualified technicians.
SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning,
removing components, or opening any enclosure.
EXPLOSION HAZARD! Always wear manufacturer approved protective safety clothing (gloves,
jacket, face shield) whenever the lamp door is open or when handling the lamp. Any local or
federal specifications take precedence over Christie's protective clothing recommendations.
1. Remove the lamp door (on page 53).
2. Remove the lamp (on page 74).
3. Remove the screw securing the anode clamp to the anode braid.
4. When the anode braid is loose, push it through the opening in the igniter cover.
5. Remove the two screws securing the igniter cover to the baseplate.
CP2420-Xe and CP4420-Xe Service Guide
020-103566-02 Rev. 1 (07-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
alignment (on page 21).
Lamp compartment
80