Page 1
Service Guide 020-103566-02 CP2420-Xe and CP4420-Xe...
Page 2
Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
CP2420-Xe and CP4420-Xe projector. Every effort has been made to make sure the information in this document is accurate and complete. However, due to continuing research, all information is subject to change without notice. Christie assumes no responsibility for omissions or inaccuracies.
Introduction Site requirements To safely install and operate the CP2420-Xe and CP4420-Xe, the installation location must meet these minimum requirements. Physical operating environment • Ambient temperature (operating) 10 to 35°C (50 to 95°F) • Humidity (non-condensing) 10% to 80% •...
Left access cover Provides access to the air filter. Security roles Only Christie authorized service technicians should perform field repair, marriage setup, and service to the unit. Theater personnel should only perform diagnostic functions, such as running the projector interrogator. After performing a procedure mandating the use of the high-security key, theater personnel must ensure the security of the system is reestablished.
To ensure you have the correct module, check the module markings and parts lists. To ensure you replace the projector module correctly, check the relevant disassembly and replacement procedures. Replace components with exact equivalents or Christie-approved replacement parts. Failure to do so may result in unsafe operation.
Service guidelines Safety precautions Learn about the safety precautions related to the Christie CP2420-Xe and CP4420-Xe projectors. This projector is intended for use in a cinema environment. General safety precautions Read all safety and warning guidelines before installing or operating the projector.
Read all safety and warning guidelines before installing the projector lamp. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • EXPLOSION HAZARD! Always wear manufacturer approved protective safety clothing (gloves, jacket, face shield) whenever the lamp door is open or when handling the lamp.
E—Represents the top view of the projector. • F—Represents the side view of the projector. For information detailing the hazard distance for each lens, refer to the CP2420-Xe and CP4420-Xe Installation and Setup Guide (P/N: 020-103555-XX). Servicing live equipment Only Christie accredited technicians who are knowledgeable about the hazards associated with hazardous voltage and high temperatures are authorized to assemble, install, and service Christie equipment.
Learn how to adjust the left and right boresight. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. Caution! If not avoided, the following could result in minor or moderate injury. •...
Learn how to adjust the top and bottom boresight. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. Caution! If not avoided, the following could result in minor or moderate injury. •...
Caution! If not avoided, the following could result in minor or moderate injury. • UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective safety clothing must be worn when performing optical adjustments or servicing the product.
Caution! If not avoided, the following could result in minor or moderate injury. • UV EXPOSURE! Protective UV safety glasses with side shields and Christie approved protective safety clothing must be worn when performing optical adjustments or servicing the product.
For the best stability, Christie recommends setting convergence while rotating the knobs in a clockwise direction. This may require first adjusting convergence by turning the knobs counter- clockwise and finalizing the convergence with a clockwise approach.
Even a small amount of dust or a fingerprint may degrade the image or cause a noticeable reduction of brightness. In environments where dust, smog, dirt, and other contaminants are higher than normal, Christie strongly recommends performing more frequent maintenance than your maintenance schedule indicates.
To ensure you have the correct module, check the module markings and parts lists. To ensure you replace the projector module correctly, check the relevant disassembly and replacement procedures. Replace components with exact equivalents or Christie-approved replacement parts. Failure to do so may result in unsafe operation.
The lamp turns off if the projector enters an overtemperature state for longer than one minute. 2. If the coolant level is below the minimum level indicator, top up the coolant with the Christie- approved coolant Glycol 740.
Typically, optical components do not need to be cleaned frequently if installed and operated in a location that meets or exceeds the environmental standard recommended by Christie. Christie recommends all cinema projectors are installed and operated in an environment meeting or exceeding Underwriters Laboratories (UL) standard 609.50 Pollution Degree 2 and ISO Class 9 Standard for...
Office Environments. Cleaning procedures must be performed by service personnel trained by Christie following consultation with Christie support. Failure to follow this recommendation could result in damage to the projector and void the warranty. Only the following optical components can be cleaned: •...
If you do not have additive-free compressed air, use an air bulb or a camel hair brush to remove dust and debris. If you have questions about the cleaning methodology, contact Christie Technical Support. 1. Prepare the projector for service.
Learn the steps for cleaning the input and output ends of the projection lens. If you do not have additive-free compressed air, use an air bulb or a camel hair brush to remove dust and debris. For any questions about the cleaning methodology, contact Christie Technical Support. 1. Prepare the projector for service.
This procedure must be performed by Christie qualified technicians. If you do not have additive-free compressed air, use an air bulb or a camel hair brush to remove the debris. If you have questions about the cleaning methodology, contact Christie Technical Support. 1. Prepare the projector for service.
4. Reassemble the projector and connect it to AC power. Rotating the lamp When the operational life of the lamp reaches halfway, Christie recommends rotating it 180° to ensure an even burn of the lamp, improve lamp performance, and extend the life of the lamp.
Page 40
EXPLOSION HAZARD! Always wear manufacturer approved protective safety clothing (gloves, jacket, face shield) whenever the lamp door is open or when handling the lamp. Any local or federal specifications take precedence over Christie's protective clothing recommendations. • EXPLOSION HAZARD! Allow sufficient time for the lamp to cool down before powering down the product, disconnecting it from AC, and opening the lamp door.
To help conserve the environment, determine which replaced product components can be recycled, reused, or sent back to Christie. Dispose appropriately and according to your local regulations. In addition, for replacement parts not being returned to Christie, reuse or recycle the replacement part packaging according to your local regulations.
Vinyl-coated or interlock knit-lined gloves • Nylon flak jacket Index of parts and modules The following table lists the parts and modules for CP2420-Xe and CP4420-Xe. Description Part Number Ventilation and cooling 12V 0.6A 4-wire 92 mm card cage exhaust fan 003-110827-XX Green/red light engine FPGA fan—CP4420-Xe only...
Remove the high-security cover to access components in the light engine and card cage compartments. Only Christie-authorized service technicians should open the high-security cover. 1. Remove front-top cover (on page 50). 2. Using the high-security key, unlock the high-security cover.
Remove the lamp door to access components in the lamp compartment. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
The lamp door interlock is fastened to the frame. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Learn how to replace the lamp. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
The douser motor is located in the lamp compartment behind the reflector assembly. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
The main blower helps keep the igniter cool. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
The main AC blower or lamp blower is located at the rear of the projector behind the lamp. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
Learn how to remove the reflectors and heat dump. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.
The UV filter is located at the front of the lamp compartment. Warning! If not avoided, the following could result in death or serious injury. • This procedure must be performed by Christie qualified technicians. • SHOCK HAZARD! Disconnect the product from AC before installing, moving, servicing, cleaning, removing components, or opening any enclosure.