Igniter; Air Flow Interlocks; Laminar Airflow Device (Lad); Lamp Replacement - Christie CP2000-SB Setup Manual

Hide thumbs Also See for CP2000-SB:
Table of Contents

Advertisement

Igniter

Clean the high voltage terminal and insulator to remove accumulated dust or dirt.

Air Flow Interlocks

The lamp fan vane switch is located within the lamp cooling compartment. The extractor vane switch is
located just inside the top duct on the projector lid. Check and, if necessary, clean the switches to remove
accumulated dust or dirt that could impede movement. Within the exhaust duct connected at the top of the
projector, adequate airflow must be maintained and routed to outside of the building. Inspect regularly and
confirm that 1) there are no obstructions or kinks within the ducting, 2) all air intake areas of the CP2000-SB
are unobstructed, and 3) exhaust airflow is within the range shown in Table 3.1. Ensure lamp wiring does not
interfere with vane switch. Refer to

Laminar Airflow Device (LAD)

Whenever checking/replacing the air filter on the side of the projector, also visually check the small square
laminar airflow device (LAD) just beyond the filter opening. The LAD should be nearly white in color-if very
dark (rare), it may have to be replaced by a qualified service technician. Contact Christie or your dealer.
4.2

Lamp Replacement

NOTE: For this procedure you will need a compatible Christie Xenon CDXL or CXL lamp as shown in
Section 8: Specifications from the CP2000-SB User Manual (020-100162-xx)-never install a lamp intended
for a different model or projector. Warning! 1) Make sure to use the correct wattage lamp supplied by
Christie. 2) Lamp replacement is to be done by a qualified service technician only. 3) EXPLOSION HAZARD
- Wear authorized protective clothing whenever the lamp door is open! Never apply a twisting or bending force
to the quartz lamp body.
Before You Begin
Read and follow all other general lamp precautions in
STEP 1: Turn Off Main AC
a. Allow the fans to run at least 10 minutes for cooling.
b. At the breaker panel on the projector, set the 3-phase MAIN AC circuit breaker to OFF.
Warning! Never attempt to remove the lamp when it is hot. The lamp is under great pressure when hot
and may explode, causing personal injury and/or property damage. Allow to cool completely.
STEP 2: Turn Off Remaining Circuit Breakers
After allowing the fans to run for at least 10 minutes, turn OFF the remaining INTERNAL and PROJEC-
TOR circuit breakers located on the breaker panel of the projector.
STEP 3: Disconnect Projector from AC Supply
Warning! SHOCK HAZARD. Disconnect from all AC at ALL wall breakers.
STEP 4: Open the Lamp Door
With protective clothing and shield on, unlock the lamp door and open it. Refer to Figure 3-5 Open Pro-
jector for Access, on page 3-4. If desired, release the latch mechanism to remove the door entirely.
STEP 5: Open Cooling Compartment
Turn knob to open the inner lamp cooling compartment and reveal the cathode end (-) of the lamp.
CP2000-SB Setup Guide
020-100249-02 Rev. 1 (05-2009)
Section 2.2 Maintaining Proper
Section 2.1 Safety Warnings and
Section 4: Maintenance
Cooling.
Guidelines.
4-3

Advertisement

Table of Contents
loading