e) Rest the anode (+) end of the lamp on the anode yoke and slip the positive lamp
connector over the bulb end.
f)
Using the 5 mm Allen key, squeeze together with the anode clamp making sure not to
place any torque on the lamp quartz tube.
For CDXL-30SD lamps, make sure the flat part of the anode end of the lamp, if
applicable, is facing in the 10 or 2 o'clock position once the lamp finger is installed in
the 14 mm threads and the clamp screw is tightened.
For all other lamp types, keep the flat part of the anode end of the lamp facing up.
g) Tighten the anode and cathode set screws.
8. Re-install the front lamp duct.
As you install the front lamp duct, lift the small light shield on the rear lamp duct cover so it
does not get jammed between the two pieces when they come together.
To make sure a good fit between the two pieces, squeeze the top and bottom cover snaps to
ensure they are locked in place. The light shield should move freely to the touch.
9. Turn the lamp and projector on by pressing and holding the Power button.
10. Record the new lamp information
a) In the left navigation menu, select Lamp Settings > Lamp Manager > + New Lamp.
b) Complete the fields in the New Lamp dialog.
c) Select Add.
11. Press and hold the light bulb icon to ignite the lamp.
12. Run LampLOC
CP2420-Xe and CP4420-Xe Service Guide
020-103566-02 Rev. 1 (07-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
on the new lamp.
Maintenance and cleaning
42

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp4420-xe

Table of Contents