Objet30 User Guide
After replacing the UV lamp:
l
l

Replacing the Material Filter

The Model and Support filters are replaced during the periodic preventive
maintenance routine (see "Preventive Maintenance Tasks" on page 6-108).
The material filters are located at the back of the materials drawer, as shown
below.
To replace the material filter:
1. Prepare the following tools and materials:
The Model and Support filters supplied in the preventive maintenance kit
are identical.
DOC-34025 Rev. I
Calibrate its power by running the UV Calibration wizard (see "Testing and
Calibrating the UV Lamp" on page 6-71). Wait at least two minutes for the
UV lamp to cool before starting the UV Calibration wizard.
Calibrate the new UV lamp again after 100 hours of printing.
Figure 6-116 Material filters
❒ protective gloves
❒ cleaning cloths
❒ wire cutter
❒ paper towels
❒ two replacement filters and cable ties (supplied in the preventive
maintenance kit)