10. Remove the UV reflector by raising it slightly, then pulling it out of the
11. Discard the old UV reflector and lamp.
Dispose of the used UV lamp in accordance with environmental and safety
requirements.
Warning: Broken UV lamp hazard
UV lamps contain mercury. Deal with broken lamps with caution.
l
l
l
l
12. Insert the UV reflector unit into the housing.
13. Make sure that the UV lamp cable is in place, inside the housing, and then
14. Replace the UV lamp cover, and tighten the securing screws.
DOC-34025 Rev. I
housing at an angle, from the bottom.
Figure 6-111 Removing the UV reflector from the UV assembly
Ventilate the room thoroughly.
Use protective gloves when collecting mercury and lamp components.
Remove spilled mercury with a method that prevents the generation of
mercury vapor, such as a syringe, packing tape or paper.
Place the broken lamp, mercury and contaminated materials in an air-tight,
non-metallic container.
tighten the securing screws.