3. Turn the Model pump assembly so that the pump is facing you.
Figure 6-142 Model pump assembly turned
4. On the top of the Model pump, locate the tube near the PRESSURE label.
5. Label (mark) the tube.
The replacement procedure is the same as for the waste pump. Continue with
step 2 on page 6-95, and then return the pump to its working position.
To return the Model pump to its working position:
1. Turn the Model pump so that it is facing the drawer.
2. Secure the Model pump to the printer with two screws.
DOC-34025 Rev. I
Insert and tighten the securing screw you removed before, and tighten the
screw that you loosened.
Figure 6-143 Model pump in the working position