Objet30 User Guide
14. Confirm the items listed in the next screen, and click Next.
Make sure that the scale for weighing the printed samples is calibrated.
Inaccurate readings may result in print heads that are not optimized for
quality printing, or a false indication that a head needs to be replaced.
15. Select the confirmation check box in the wizard screen, and click Next.
DOC-34025 Rev. I
Figure 6-71 Preparations confirmation
Figure 6-72 Wizard progress
The printer prepares itself for printing (by running the reinitaite process).
Then, 6 or 12 samples are printed on the build tray, depending on the
printer model. This can take up to 80 minutes.
6 Operating and Maintaining the Printer
6-54