Objet30 User Guide
5. If necessary, clean the glass over the UV sensor with a cleaning cloth and
6. Confirm the items in the wizard screen, and click Next.
DOC-34025 Rev. I
90% alcohol (IPA).
Do not use the abrasive cleaning pad to clean the glass.
The UV lamp powers up and stabilizes. (This takes several minutes.) Then,
the print block passes over the sensor and the wizard compares the
measured radiation to the recommended level.
Figure 6-95 UV measurement progress
6 Operating and Maintaining the Printer
6-73