To test and calibrate UV lamp radiation:
1. Start the UV Calibration wizard from the Options menu.
2. In the following screen, select UV Intensity Calibration to adjust the
3. Make sure that the build tray is clear (empty). Confirm this in the wizard
4. Expose the UV sensor by sliding its cover to the right, and check that the
DOC-34025 Rev. I
lamp's radiation level to the acceptable range.
Figure 6-92 UV Calibration selection
screen, and click Next.
The following screen appears.
Figure 6-93 Printer preparation
glass is clean.
Figure 6-94 UV sensor exposed