The Do Not Remove button illuminates and flashes.
b. Wait until the flashing stops and the Do Not Remove button is no longer illuminated.
c. Push the Do Not Remove button and then remove the drive.
To replace the component, reverse the removal procedure.
Removing and replacing an M.2 SSD
Prerequisites
Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available.
Procedure
1.
Back up all server data.
2.
If installed, remove the bezel.
3.
Power down the server.
4.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5.
Disconnect all peripheral cables from the server.
6.
Do one of the following:
•
Extend the server from the rack.
•
Remove the server from the rack.
7.
Remove the access panel.
8.
Remove the primary PCI riser cage.
9.
Remove the M.2 SSD enablement board.
10. Remove the M.2 SSD.
Removal and replacement procedures